TABLES PERNR.
INFOTYPES:
1000,1001.
INFOTYPES 0001
MODE N.
DATA SOBID
TYPE PLOG-OBJID.
DATA: BEGIN OF
IT_T500P OCCURS 0,
PERSA TYPE T500P-PERSA,
NAME1 TYPE T500P-NAME1,
END OF IT_T500P.
DATA: BEGIN OF
IT_T501T OCCURS 0,
PERSG TYPE T501T-PERSG,
PTEXT TYPE T501T-PTEXT,
END OF IT_T501T.
DATA: BEGIN OF
IT_T527X OCCURS 0,
ORGEH TYPE T527X-ORGEH,
ORGTX TYPE T527X-ORGTX,
END OF IT_T527X.
DATA SOB(8) TYPE
N.
START-OF-SELECTION.
SELECT PERSA NAME1 FROM T500P INTO TABLE
IT_T500P.
SELECT PERSG PTEXT FROM T501T INTO TABLE
IT_T501T WHERE SPRSL = SY-LANGU.
SELECT ORGEH ORGTX FROM T527X INTO TABLE
IT_T527X WHERE SPRSL = SY-LANGU.
GET PERNR.
CALL FUNCTION 'RH_READ_INFTY_1000'
EXPORTING
* AUTHORITY = 'DISP'
* WITH_STRU_AUTH = 'X'
PLVAR = '01'
OTYPE = 'S'
OBJID = PERNR-PLANS
* ISTAT = ' '
* EXTEND = 'X'
* BEGDA = '19000101'
* ENDDA = '99991231'
* CONDITION = '00000'
* SORT = 'X'
TABLES
I1000 = P1000
* OBJECTS =
EXCEPTIONS
NOTHING_FOUND = 1
WRONG_CONDITION = 2
WRONG_PARAMETERS = 3
OTHERS = 4
.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER
SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3
SY-MSGV4.
ENDIF.
CALL FUNCTION 'RH_READ_INFTY_1001'
EXPORTING
* AUTHORITY = 'DISP'
* WITH_STRU_AUTH = 'X'
PLVAR = '01'
OTYPE = 'S'
OBJID = PERNR-PLANS
* ISTAT = ' '
* EXTEND = 'X'
* SUBTY = ' '
* BEGDA = '19000101'
* ENDDA = '99991231'
* CONDITION = '00000'
* SORT = 'X'
* WITH_EV = ' '
* ADATA = 'X'
* AUTH_SOBID = ' '
TABLES
I1001 = P1001
* OBJECTS =
EXCEPTIONS
NOTHING_FOUND = 1
WRONG_CONDITION = 2
WRONG_PARAMETERS = 3
OTHERS = 4
.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER
SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3
SY-MSGV4.
ENDIF.
READ TABLE IT_T500P WITH KEY PERSA =
PERNR-WERKS .
READ TABLE IT_T501T WITH KEY PERSG =
PERNR-PERSG .
READ TABLE IT_T527X WITH KEY ORGEH =
PERNR-ORGEH .
READ TABLE P1000 WITH KEY LANGU = SY-LANGU.
READ TABLE P1001 WITH KEY RSIGN = 'B'
RELAT = '002'.
SOBID = P1001-SOBID.
REFRESH P1001[].
CALL FUNCTION 'RH_READ_INFTY_1001'
EXPORTING
* AUTHORITY = 'DISP'
* WITH_STRU_AUTH = 'X'
PLVAR = '01'
OTYPE = 'S'
OBJID = SOBID
* ISTAT = ' '
* EXTEND = 'X'
* SUBTY = ' '
* BEGDA = '19000101'
* ENDDA = '99991231'
* CONDITION = '00000'
* SORT = 'X'
* WITH_EV = ' '
* ADATA = 'X'
* AUTH_SOBID =
TABLES
I1001 = P1001
* OBJECTS =
EXCEPTIONS
NOTHING_FOUND = 1
WRONG_CONDITION = 2
WRONG_PARAMETERS = 3
OTHERS = 4
.
IF SY-SUBRC <> 0.
MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER
SY-MSGNO
WITH SY-MSGV1 SY-MSGV2 SY-MSGV3
SY-MSGV4.
ENDIF.
READ TABLE P1001 WITH KEY RSIGN = 'A'
RELAT = '008'.
SOB = P1001-SOBID.
RP-READ-INFOTYPE SOB 0001 P0001 PN-BEGDA
PN-ENDDA.
WRITE: PERNR-PERNR,
PERNR-SNAME,PERNR-WERKS,IT_T500P-NAME1,PERNR-PERSG,IT_T501T-PTEXT,PERNR-ORGEH,IT_T527X-ORGTX,PERNR-PLANS,P1000-STEXT,P0001-SNAME.